In order to streamline support requests and better serve you, we utilize a support ticket system. Every support request is assigned a unique ticket number which you can use to track the progress and responses online. For your reference we provide complete archives and history of all your support requests.
|

|
1
How does the system know what event caused the Down Time?
A: When a Down Time has been detected, the Data Logger Program will trigger a “Delay Screen” to display on the Operator HMI Touch screen. Through this “Delay Screen”, the operator will can select the reason for downtime. Delays are broken down into three sections: Area, Subarea, and Reason.
2
How does the system detect down time?
A: The Insight Data Logger Program, in conjunction with few lines of PLC code, will monitor the Shredder Motor current. The Insight Logger will prompt a Delay Screen on the Shredder Operator HMI any time the current drops below 10-12% of Idle Current for around 10-15 seconds. The System records when the delay occurred and ends the delay when motor current rises above the Idle Current set point.
3
What is the Insight Plant Analysis Platform?
A: The Insight Plant Analysis System (IPAS) is a plant management tool created for Shredder Yard Managers and Maintenance Personnel. With IPAS, Yard Managers can gauge the overall efficiency, production, and trouble areas of the entire Shredder Operation.
|
|

|
New Users
Setting Up New Users
The following link is the procedure for setting up new users in the Insight Plant Analysis Platform... click here ...
System Backup
Automatic System Backup
The Insight Data Logger program comes with a self back up feature. Upon installation Insight PDS will configure the Insight Data Logger Program to automatically back up the Activity and Config databases to a folder on a secondary physical hard drive on the Data Collections Server computer every Saturday at Midnight. We will inform the site IT on the location of this directory. Variable databases are not automatically backed up.
Recommended Files and Folders for Manual Back Up We recommend backing up all files in the Automatic Back Up Folder, the EditAct.mdb, and all Variable Databases (all mdb files that start with “V”) in the PPA Data Folders.
Error '70'
Runtime Error '70': Permission Denied
This error comes in sometimes when an individual tries to create a report. This may be resolved by adjusting a security parameter with in the +Com setting of the Data Collection Server.
The following link is a Microsoft Tech Note on has to change these settings.
http://support.microsoft.com/kb/247394
|
|
|
| |
|